Fire inspection

#

Testing

#

Maintenace

Maintenance and Repair

Air Leaks

Supervised Device Failure

Water Leaks

Most dry sprinkler systems have a life expectancy of roughly 15-25 years depending on pipe thickness. Pinhole leaks eat away at the pipe until it bust through, causing heavy demand of the air compressor and possible false system activation, and building damage.

Water Leaks

Supervised Device Failure

Water Leaks

Water leaks may appear in the vicinity of a wall or fire sprinkler causing brown stains and paint bubbling on ceilings/walls.  Water leaks can exist for a while prior to showing evidence, resulting in mold and extended building damage and remediation.

Supervised Device Failure

Supervised Device Failure

Supervised Device Failure

Supervisory alarms are often caused by an electrically shorted device, or broken tamper switch.  We will find, test, and replace these devices and keep your system in a "Normal" status.

Loaded Sprinkler Heads

Fouled Check Valve, Relief Port

Supervised Device Failure

Vents, heavy air transfer areas, kitchens, and pools are highly susceptible to corrosion and dirt.  It is the most critical areas where they get the dirtiest.  Let us take care of this for you!

Frozen Systems/Risers/Loops

Fouled Check Valve, Relief Port

Fouled Check Valve, Relief Port

Its Montana, and we regularly freeze our butts off.  Your fire sprinkler system is no different and can freeze causing significant damage and system impairment to your building.  We offer 24/7 Emergency service and will respond to your emergency, without charging extra fees!

Fouled Check Valve, Relief Port

Fouled Check Valve, Relief Port

Fouled Check Valve, Relief Port

When you have a failed test report, backflow leaks, or a replacement is needed - our highly trained technicians are ready and equipped to handle the most difficult jobs.

Dry Valve Rebuild/Replace

Air Compressor/Air Maintenance Device

Air Compressor/Air Maintenance Device

Dry system valves require regular testing and maintenance for proper function in the event of a fire.  If test results prove inadequate or it leaks inside the valve, our team is ready to repair or replace any component causing trouble.

Air Compressor/Air Maintenance Device

Air Compressor/Air Maintenance Device

Air Compressor/Air Maintenance Device

Unfortunately, air compressor motors fail, tanks can rot, or they can no longer detect and regulate system air pressure.  Our licensed technicians will diagnose, provide temporary coverage, and repair your air system. 

Pressure Gauge Replacement

Air Compressor/Air Maintenance Device

Pressure Gauge Replacement

According to nfpa25, System pressure gauges are to be replaced or tested every 5 years for accuracy.  Our gauges are rated to 300# and can be purchased or installed at any point you desire, however we typically do it every 5 years in accordance with a required 5-year internal/obstruction investigation. 

Valve Packing Replacement

Clogged Drum Drip, Inspector Test

Pressure Gauge Replacement

Oscillating Stem and Yoke (OS&Y) valves are known for tight turns and leaking stems.  We will repair your existed valves and packing and, if required, replace any valves beyond repair. 

Clogged Drum Drip, Inspector Test

Clogged Drum Drip, Inspector Test

Clogged Drum Drip, Inspector Test

Years of service and proper testing can eventually lead to clogged drains and inspection points due to corrosion and wear/tear.  Aflame Fire Protection is equipped to handle this situation in a timely manner! 

Damaged Piping/Sprinkler Heads

Clogged Drum Drip, Inspector Test

Clogged Drum Drip, Inspector Test

It is not uncommon to have a system/component obliterated by a forklift, pallet, truck, etc. We specialize in responding to these situations fast and repairing to current code requirements. 