Welcome to aflame fire, your local fire protection Provider

Find out more
#

Inspection

#

Testing

#

Maintenace

Inspection Services

Wet Systems

Pre-Action/Deluge Systems

Wet Systems

Wet sprinkler systems require a minimum flow inspection and visual walk through annually. We will take care of this for you on a quarterly, semi-annual, or annual basis.

Dry Systems

Pre-Action/Deluge Systems

Wet Systems

Dry system inspection is imperative to proper function.  Dry valves are sensitive in nature and can actually corrode shut, making your system useless in the event of a fire.  Our technicians are trained to inspect and prolong your dry pipe sprinkler systems.

Pre-Action/Deluge Systems

Pre-Action/Deluge Systems

Pre-Action/Deluge Systems

Computer Servers, MRI machines, IT closets, airplane hangars, or lumber mills are no match for our team of inspectors. We can safely and accurately inspect these systems and provide protection for your critical infrastructure.

Backflow Prevention

5-Year Obstruction/Internal

Pre-Action/Deluge Systems

The pipes of sprinkler systems erode over time, into the water of the system.  Without backflow prevention, this water can be easily pulled into the domestic water supply and contaminate your drinking water. We specialize in highly accurate testing and can resolve any deficiencies in a timely manner.

5-Year Obstruction/Internal

5-Year Obstruction/Internal

5-Year Obstruction/Internal

A combination of water and oxygen leads to the breakdown of interior walls of metal piping, clogging vital areas and components of the system. Our experienced team will find, test, and document this process over the life of your system. 

Fire Pump

5-Year Obstruction/Internal

5-Year Obstruction/Internal

Don't shy away from that scary fire pump in the shed. Aflame Fire Protection will inspect, test, and maintain your diesel and electric fire pump.

Standpipes

Fire Department Connections

Standpipes

Standpipes in stairwells are vital in the fire department's ability to battle a raging fire.  The team at Aflame Fire will verify proper function in accordance with nfpa25 standards.

Hydrants

Fire Department Connections

Standpipes

Fire hydrants are often the second line of defense against a fire, with the first being activation of a fire sprinkler system.  Our team can verify flow and code requirements for city/personal hydrant systems. 

Fire Department Connections

Fire Department Connections

Fire Department Connections

Due to the moisture present and heavy oxygen content, fire department connections (FDC) often corrode and cause the check valve to stick shut.  This condition prevents the fire department from dispersing extra water on the blaze.  Nfpa25 requires hydrostatic testing every 5 years.